Hi Jaakko,

I have a question regarding the output from SERPENT 1.1.19.
Does it produce decay heat precursors decay rates (1/sec)?

Thank you in advance!
Sasha.
by Sasha
Tue Oct 20, 2015 6:02 pm
Forum: Bugs, problems, questions & feeback
Topic: Output data from SERPENT 2.1.24
Replies: 4
Views: 6879

Re: Output data from SERPENT 2.1.24

Hi Jaakko,

Thank you very much for the clarification!

With best regards,
Sasha.
by Sasha
Thu Oct 15, 2015 6:50 pm
Forum: Bugs, problems, questions & feeback
Topic: Output data from SERPENT 2.1.24
Replies: 4
Views: 6879

Output data from SERPENT 2.1.24

Hello, Sorry, I have a question regarding the output data from SERPENT 2.1.24. I've used SERPENT 1.1.19 for the generation of cross-section data. These data are used as an input for a reactor physics code, and certain variables must be always provided to this code. I would like to use SERPENT 2.1.24...
by Sasha
Fri Sep 11, 2015 5:03 pm
Forum: Bugs, problems, questions & feeback
Topic: Flux Interpretation and Units in SERPENT
Replies: 2
Views: 3898

Re: Flux Interpretation and Units in SERPENT

Thank you very much for the clarification!
Sasha.
by Sasha
Fri Sep 11, 2015 4:02 pm
Forum: Bugs, problems, questions & feeback
Topic: LAMBDA in the Delayed Neutron Parameters Output
Replies: 5
Views: 6828

Re: LAMBDA in the Delayed Neutron Parameters Output

Hello Jesse,

Looking at the order of magnitudes of LAMBDA, *_LIFETIME, *_GEN_TIME, I think that you're right.

Thank you very much for the clarification!

With best regards,
Sasha.
by Sasha
Thu Sep 10, 2015 5:51 am
Forum: Bugs, problems, questions & feeback
Topic: LAMBDA in the Delayed Neutron Parameters Output
Replies: 5
Views: 6828

LAMBDA in the Delayed Neutron Parameters Output

Dear Jaakko, Excuse me, two questions regarding LAMBDA in the delayed neutron parameters part of the output (SERPENT 2.1.24): 1) Is my understanding correct that LAMBDA=Lambda_eff, which is the prompt neutron reproduction time, and It is equal to l_eff (the effective prompt neutron lifetime)/keff (t...
by Sasha
Wed Sep 09, 2015 6:58 pm
Forum: Bugs, problems, questions & feeback
Topic: Flux Interpretation and Units in SERPENT
Replies: 2
Views: 3898

Flux Interpretation and Units in SERPENT

Dear Jaakko, I've seen several discussions on the forum regarding neutron flux estimation using detectors and flux units. Excuse me, I still have a few questions (Note: I am using Serpent 2.1.24): 1) TOT_FLUX is the total flux integrated over the geometry and all energy groups. In the User's Manual,...
by Sasha
Fri Aug 21, 2015 8:34 pm
Forum: Input
Topic: Shuffle option
Replies: 2
Views: 3986

Re: Shuffle option

Hi Tuomas,

Thank you very much! I will try this option.

Sincerely,
Sasha.
by Sasha
Thu Aug 20, 2015 9:51 pm
Forum: Input
Topic: Shuffle option
Replies: 2
Views: 3986

Shuffle option

Hello Jaakko, Sorry, I have two questions regarding the shuffle option and modelling of control rods. I'm working on the modelling of a lead-cooled reactor using Serpent 2.1.24. I need to take into account extraction of control rod banks during burnup. I was thinking to create several lattices repre...