by PRoux
Tue Feb 23, 2021 7:27 pm
Forum: Methods
Topic: Using Input Macroscopic Cross Section Libraries
Replies: 3
Views: 397

Re: Using Input Macroscopic Cross Section Libraries

Okay, that is what I thought, but it doesn't hurt to check!
Thanks Ana and Jaakko.
by PRoux
Tue Feb 23, 2021 6:10 pm
Forum: Methods
Topic: Using Input Macroscopic Cross Section Libraries
Replies: 3
Views: 397

Using Input Macroscopic Cross Section Libraries

Serpent users and developers

I was wondering if it was possible to use a macroscopic cross section library as an input in a Serpent input?
So basically, instead of using the ACELIBS, is it possible to provide a path to a macroscopic library? If so, is there a specific format?

Thanks !
by PRoux
Mon Aug 17, 2020 5:09 pm
Forum: Bugs, problems, questions & feeback
Topic: S(a,b) ENDF/BVII.1
Replies: 7
Views: 6183

Re: S(a,b) ENDF/BVII.1

Serpent Developers, Thank you, Jaakko, for the update. A follow-up though: Using the (useful) information found in this thread: https://ttuki.vtt.fi/serpent/viewtopic.php?f=15&t=3452&p=10974&hilit=thermal+scattering#p10974 I hooked up ENDF/B.VIII.0 with the thermal scattering data from ENDF/B-VII.0....
by PRoux
Tue Jun 02, 2020 3:27 am
Forum: Users
Topic: Large volume of water
Replies: 5
Views: 1598

Re: Large volume of water

Hello Serpent users, The issue was resolved. To make Serpent print the actual volume of the material in the case of "filler" materials (by "filler", I mean a material that is occupying the outside universe), in that case Water , the volume of the material actually needs to be specified. For instance...
by PRoux
Wed Mar 01, 2017 3:09 am
Forum: Users
Topic: Flux Spectrum Calculation
Replies: 9
Views: 6244

Re: Flux Spectrum Calculation

Hello, I am having similar issues as Yousef, I am little confused on what I am obtaining from the detectors. I am trying to compare the flux with another code, for a thermal reactor. I just need the total neutron flux per unit lethargy averaged over my system . I am so far looking only at one assemb...
by PRoux
Tue Oct 11, 2016 3:33 am
Forum: Users
Topic: Reflective Boundary Conditions on selected hexagonal faces
Replies: 1
Views: 1884

Reflective Boundary Conditions on selected hexagonal faces

Hello ! If I understood well in the Manual, Serpent has three types of Boundary Condtions (BC) available: - Infinite 2D; - Radially infinite and Axially finite 3D; - 3D infinite. More practically, It is possible to chose x, y or z as symmetry axis. How does it apply to hexagonal geometries ? I was w...
by PRoux
Fri Oct 07, 2016 12:23 am
Forum: Users
Topic: Thermal Scattering For Graphite - grph.17t vs grph.27t
Replies: 1
Views: 2083

Thermal Scattering For Graphite - grph.17t vs grph.27t

Hi ! I am trying to compare two different thermal scattering libraries for graphite. My entry for the thermal scattering library grph.17t is: mat porous_c sum vol 118.08 tmp 1200 moder graphite_1200 6000 rgb 240 255 240 6000.83c 5.2646E-02 % C therm graphite_1200 grph.17t This configuration works co...