Criticality source calculation with external sources

Old bugs, solved problems and other topics that are no longer relevant are moved here
Post Reply
User avatar
Jaakko Leppänen
Site Admin
Posts: 2054
Joined: Thu Mar 18, 2010 10:43 pm
Security question 2: 0
Location: Espoo, Finland
Contact:

Criticality source calculation with external sources

Post by Jaakko Leppänen » Wed Sep 08, 2010 4:58 pm

Version 1.1.13 has a problem related to criticality source calculation when the initial source guess is given by the "src" card. The calculation stops with message:

Code: Select all

Fatal error in function Transport:

Mismatch in source weight

Simulation aborted.
This problem can be fixed by adding line:

Code: Select all

DATA[DATA_TOT_SRC_WGT] = 0.0;
in samplesrc.c, after line 65 (function call to ExternalSource). The problem will be fixed in the next update.
- Jaakko

User avatar
Jaakko Leppänen
Site Admin
Posts: 2054
Joined: Thu Mar 18, 2010 10:43 pm
Security question 2: 0
Location: Espoo, Finland
Contact:

Re: Criticality source calculation with external sources

Post by Jaakko Leppänen » Tue Nov 16, 2010 12:05 pm

This problem was fixed in update 1.1.14.
- Jaakko

Post Reply